Product System
Battery on line monitoring device
Communication mode: RS485,
Overall voltage monitoring range: dc0v ~ 220V;
Monitoring range of single battery voltage: DC2V ~ 24V;
Current monitoring range: 0 ~ 1000A;
Environmental temperature monitoring: 0 ~ 100 ℃;
Measurement range of internal resistance: 0.1M Ω~ 100m Ω。
On line monitoring device of fluorescence optical fiber temperature measurement
RS485 communication interface
Temperature range: 40-200 ℃,
Temperature measurement accuracy: ± 1℃,
Number of temperature measuring channels: 6.
On line monitoring device for action characteristics of circuit breaker
Communication mode: network port or RS485 signal output
Installation mode: wall mounted
Power supply: AC220V
It can realize real-time monitoring of characteristic parameters such as opening and closing time and current of AC / DC circuit breaker.
Working power: AC 220V,
dehumidification capacity: 400ml/d,
power: 60W,
the whole machine working power (dehumidification) can be customized,
RS485 communication, the heater control function and data communication function can be extended and wireless receiver can realize communication function. Switch cabinet and ring network cabinet are commonly used.
Door state sensing distance: 20-30mm
Signal output: normally open / normally closed
Electrical parameters: maximum power 10W, maximum voltage 100V
Maximum current 0.5A (customizable)
Working power supply: DC 12V
Carrier frequency: 38kHz
Remote control distance: 10M
Temperature probe: - 10 ℃~ + 60 ℃
Weight: 90g
Power consumption: DC 12V, < 100mA
Alarm: can be external active or passive alarm
Unlocking mode: mobile app, QR code identification, password, induction
Card, mechanical key, etc
Card reading distance: 0-15cm
Card reading time: < 1s
Communication interface: RS485, RJ45, Mini USB
Controllable gate output: 1 / 2 / 4 gate optional
Digital processor 12 / 8 bits 8 MHz
Continuously adjustable sensitivity, high protection range, sensitivity: 9m distance
Power input 9-16vdc
The alarm output is normally closed.
Working voltage DC24 V
Range: 0-30m / S
Dynamic response time ≤ 0.5s
Starting wind speed: ≤ 0.2m/s
Output interface: RS-485 / 4 ~ 20mA
Power supply voltage: DC 12 ~ 24 V
Gas type: PM2.5
Range: 0 ~ 1000 μ g/m3
Accuracy: < ± 3%
Output signal: 4 ~ 20mA or RS-485
Overall dimension (mm): 117 (L) * 86 (W) * 41 (H)
Power supply: DC24 V
Measurement range: vibration speed 0-200 mm / S (range can be customized)
Vibration acceleration 0-50g, vibration displacement 0-8000um, output mode: 4-20mA / RS485, response frequency: 2hz-2000hz (acceleration), 5hz-2000hz (velocity), 10hz-2000hz (vibration displacement)
Installation method: permanent magnet adsorption installation or adhesive installation
Power supply voltage: DC 9-24 V
Illumination accuracy: ± 7%
Light intensity: 0-20000 lux (customizable)
Output interface: RS485 / 4 ~ 20mA
Overall dimension (mm): 117 (L) * 86 (W) * 41 (H)
Power supply voltage: dc12-24 V
Detection range: 10-100m, optional
Beam number: 2-10 beam optional, beam frequency: 4-segment frequency conversion
Detection mode: cut off two adjacent beams and give an alarm
Alarm output mode: relay nodeNC / NC.
Working power supply: DC 9 ~ 24 V
Measurement frequency range: 20Hz ~ 12.5khz
Noise measurement range: 30dB ~ 120dB
Signal output: RS485
Power supply: dc9 ~ 12V
Working current: static 45mA (common relay output) or 10mA (electronic relay output) alarm 15mA
Inductor: three sets of special dual structure with low noise
Coverage: 12m × 12m (typical value)
Alarm port: normally open and normally closed alarm port, contact capacity 100mA / 30VDC