Product System

Product System

Product System

C-9644 smoke sensor


This product uses a first-line brand smoke gas sensor probe to measure the concentration of smoke in the air, and it has a high sensitivity to smoke in the higher concentration range. This product uses imported 485 chips and multiple protections for the 485 interface, which can effectively cope with the interference of surges and pulses in the industrial field. It can communicate reliably within the full baud rate range of 1200-115200, which is at the leading level in the industry.

JC-SW-ZN03 water level sensor


With reverse polarity and current limit protection; laser resistance temperature compensation; programmable adjustment; anti-vibration, anti-shock, anti-radio frequency electromagnetic interference: strong overload and anti-interference ability, economical, practical and stable.

On-line monitoring of partial discharge of cable joints (110kV and above)


It can detect basic partial discharge parameters such as discharge volume, discharge phase, and discharge times, and can provide statistics of relevant parameters according to customer requirements. Minimum measurement discharge volume: 1mV; Measurement frequency: 300kHz-30MHz; Discharge pulse resolution: 10µs; Phase resolution: 0.18°. It can display power frequency periodic discharge graph, two-dimensional (q-φ, N-φ, N-q) and three-dimensional (N-q-φ) discharge spectrogram.

On-line monitoring system for circulating current of power cable sheath


It can monitor the running status of the ground current of the high-voltage cable line in real time, end the time-consuming and laborious situation of the traditional periodic inspection method; reduce the risk of theft of the cable line cross interconnection wire, ground wire, cross interconnection box, and grounding box.

Transmission line haze meteorological monitoring and flashover warning system


The substation haze meteorological monitoring and flashover warning system consists of four parts: haze meteorological parameter monitoring unit, data concentrator, intelligent substation IED, and haze meteorological analysis software system. The haze meteorological parameter monitoring unit, data concentrator, haze meteorological analysis software system, etc. are the same as the haze meteorological monitoring and flashover warning system for transmission lines. The intelligent substation IED completes the transmission of control commands at the station control layer and the transmission of data concentrator information, and analyzes and stores the data collected by the monitoring terminal. The intelligent substation IED sends commands and receives data to the data concentrator through the RS485 interface, adopts the IEC61850 protocol and transmits the data to the background server through optical fiber communication.

Transmission line breeze vibration monitoring device


The transmission line breeze vibration monitoring device organically combines computer technology, electronic information technology, automation technology, network communication technology and geographic information technology. The breeze monitoring vibration sensor is installed at 89mm of the wire clamp outlet of the transmission line that needs to be monitored, and the wire is measured in real time. The bending amplitude (or reverse amplitude) of the wire at 89mm from the outlet of the wire clip relative to the wire clip. This value is used to measure the dynamic bending strain of the wire at the outlet of the wire clip. After data processing, the data is uploaded to the low-power radio frequency module. Monitor the host on the tower. Realize remote online monitoring of wind-induced vibration, icing characteristics and operating environment of transmission lines. Real-time online monitoring of the breeze vibration conditions of the conductor and ground line, and at the same time monitor the on-site environmental temperature, humidity, wind speed, wind direction and other meteorological conditions, use Any one of a variety of communication methods such as China Unicom’s public network, optical fiber, wireless relay, etc., completes the remote real-time transmission of various field data, provides on-site vibration information through background analysis software and expert knowledge, and sends out forecasts in time The warning signal effectively prevents major accidents such as stock breakage.

JC-WS-ZN01 Smoke Detector


Self-check: Press the check button, the LED of the detector is always on, and an alarm sound is emitted at the same time (Note: The self-check only detects the internal functions of the detector itself, and there is no relay signal output during the self-check). Work: Normally, the indicator light of the detector will flash about every 6 seconds. The detector automatically detects the concentration of smoke in the surrounding environment, and automatically compensates for sensitivity according to the environment in which it is used. When the smoke density is close to the alarm value, the detector speeds up the intelligent calculation of the smoke density trend, and the alarm indicator starts to flash. If the calculation result reaches or exceeds the alarm value, the detector will start audible and visual alarm and start the relay output. When the smoke concentration in the surrounding environment drops below the alarm value, the detector automatically resumes its normal working state.

JC-FJ-ZN01 Intelligent Fan Control Unit


Overload protection, stable operation Customizable output control power Strong anti-interference and stable performance

SF6 micro water density transmitter


No emissions, environmental protection, economy, safety and reliability Online monitoring of SF6 circuit breakers or combined electrical appliances such as micro water, density, temperature and other parameters Realize micro-water pressure and temperature compensation, density temperature compensation, make micro-water and density data true and reliable Adopt sensors with a variety of patented technologies and self-calibration functions The acquisition unit can be put into operation and exit without affecting the state of the main equipment, and does not affect the normal operation of the main equipment The internal circulation technology is used inside the acquisition unit to greatly improve the sampling accuracy

Transmission line image monitoring device


Transmission line image monitoring device uses GPRS/CDMA/3G/optical fiber/WiFi and other methods to transmit data to condition monitoring agent device (CMA) or master station system, and can realize the focus, aperture, and orientation of the camera under remote command control And the setting and adjustment of PTZ preset position. This device can be used in conjunction with a wire equivalent ice coating thickness monitoring device, an anti-theft monitoring device, etc., to provide the latter with convenient and intuitive on-site image information.

GS200-H2 Intelligent Integrated Gas Detector (Hydrogen)


The toxic and harmful gas detector is a new type of gas detection instrument produced by our company. This machine adopts high-performance catalytic combustion gas-sensing components and microcontroller technology, combined with sophisticated SMD technology. It has good repeatability and temperature and humidity characteristics. Advantages such as long service life and convenient operation. It is suitable for the concentration and temperature and humidity detection of methane (CH4), oxygen (O2), carbon monoxide (CO), hydrogen sulfide (H2S) and hydrogen (H2) in industrial environments (especially underground pipe corridors). The toxic and harmful gas detector converts the gas concentration signal in the air into a digital signal, and is equipped with RS485 interface and WIFI transmission function. The gas concentration and temperature and humidity data measured in the detector can be accessed only through the RS485 interface or WIFI signal (can be customized according to requirements).

Transmission line video monitoring device


The transmission line video monitoring device uses advanced digital video compression technology, low power consumption technology, GPRS/CDMA/3G wireless communication technology, new energy and other technologies, which can be used for the transmission line body and the line corridor environment (the transmission line body includes the transmission wire , Poles, towers, insulator strings and spacers, wire clamp fittings, etc., the line corridor environment includes foundations, vegetation, surrounding personnel, vehicle activities, etc.) to monitor the scene to take photos or videos; the device adopts GPRS/CDMA/3G/optical fiber/WiFi, etc. The data is transmitted to the condition monitoring agent device (CMA) or the master station system, and under the control of remote instructions, the camera's focal length, aperture, position and pan/tilt preset position can be set and adjusted.

Transmission line wildfire monitoring and early warning system


Transmission line wildfire monitoring device integrates infrared thermal imaging unit, over-temperature detection unit, visible light camera unit, fire monitoring analysis unit, pan/tilt* positioning unit, sound and light alarm unit, video compression unit, wireless communication unit, power supply system and other parts composition. It can output two video signals at the same time, with infrared thermal imaging over-temperature detection and visible light fire detection functions, and can analyze according to the confidence coefficient model, and automatically give fire alarm information.

Three-span video monitoring device for power transmission line


Support the requirements of the enterprise standard interface B of "Grid Video Monitoring System and Interface", and support access to the unified video platform of the State Grid Corporation Information Intranet The device has a built-in security encryption chip, which realizes the encrypted transmission of interface B signaling, guarantees data security, and meets the network security requirements of the State Grid The camera has infrared function, supports night vision function, meets the needs of night monitoring, and the irradiation distance is ≥180 meters Support pan/tilt control function, pan/tilt supports up, down, left, right movement and speed control; lens supports zoom adjustment control Embedded system design, built-in hardware watchdog, 7×24 hours continuous operation It has the function of short-distance wireless joint debugging under the tower, which is convenient for maintenance Meet the various technical indicators and functional requirements of the *power grid for three-span video equipment Has a functional test report and type test report issued by a third-party testing agency

Meteorological line monitoring device for transmission line


The master station system can store, count and analyze the collected information, and display it to users in the form of reports, curves, and statistical graphs. When the monitoring value is abnormal, the system will send out early warning messages in a variety of ways to remind the management personnel.
< 1...313233...37 >