Product System

Product System

Product System

On line monitoring device for action characteristics of circuit breaker


Communication mode: network port or RS485 signal output Installation mode: wall mounted Power supply: AC220V It can realize real-time monitoring of characteristic parameters such as opening and closing time and current of AC / DC circuit breaker.

Intelligent dehumidifier


Working power: AC 220V, dehumidification capacity: 400ml/d, power: 60W, the whole machine working power (dehumidification) can be customized, RS485 communication, the heater control function and data communication function can be extended and wireless receiver can realize communication function. Switch cabinet and ring network cabinet are commonly used.

Door magnetic sensor


Door state sensing distance: 20-30mm Signal output: normally open / normally closed Electrical parameters: maximum power 10W, maximum voltage 100V Maximum current 0.5A (customizable)

Air conditioner controller


Working power supply: DC 12V Carrier frequency: 38kHz Remote control distance: 10M Temperature probe: - 10 ℃~ + 60 ℃ Weight: 90g

The access controller


Power consumption: DC 12V, < 100mA Alarm: can be external active or passive alarm Unlocking mode: mobile app, QR code identification, password, induction Card, mechanical key, etc Card reading distance: 0-15cm Card reading time: < 1s Communication interface: RS485, RJ45, Mini USB Controllable gate output: 1 / 2 / 4 gate optional

Glass breakage detector


Digital processor 12 / 8 bits 8 MHz Continuously adjustable sensitivity, high protection range, sensitivity: 9m distance Power input 9-16vdc The alarm output is normally closed.

Wind speed sensor


Working voltage DC24 V Range: 0-30m / S Dynamic response time ≤ 0.5s Starting wind speed: ≤ 0.2m/s Output interface: RS-485 / 4 ~ 20mA

PM2.5 sensor


Power supply voltage: DC 12 ~ 24 V Gas type: PM2.5 Range: 0 ~ 1000 μ g/m3 Accuracy: < ± 3% Output signal: 4 ~ 20mA or RS-485 Overall dimension (mm): 117 (L) * 86 (W) * 41 (H)

Transformer vibration sensor


Power supply: DC24 V Measurement range: vibration speed 0-200 mm / S (range can be customized) Vibration acceleration 0-50g, vibration displacement 0-8000um, output mode: 4-20mA / RS485, response frequency: 2hz-2000hz (acceleration), 5hz-2000hz (velocity), 10hz-2000hz (vibration displacement) Installation method: permanent magnet adsorption installation or adhesive installation

Illuminance sensor


Power supply voltage: DC 9-24 V Illumination accuracy: ± 7% Light intensity: 0-20000 lux (customizable) Output interface: RS485 / 4 ~ 20mA Overall dimension (mm): 117 (L) * 86 (W) * 41 (H)

Infrared grating detector


Power supply voltage: dc12-24 V Detection range: 10-100m, optional Beam number: 2-10 beam optional, beam frequency: 4-segment frequency conversion Detection mode: cut off two adjacent beams and give an alarm Alarm output mode: relay nodeNC / NC.

Transformer noise sensor


Working power supply: DC 9 ~ 24 V Measurement frequency range: 20Hz ~ 12.5khz Noise measurement range: 30dB ~ 120dB Signal output: RS485

Infrared three detector


Power supply: dc9 ~ 12V Working current: static 45mA (common relay output) or 10mA (electronic relay output) alarm 15mA Inductor: three sets of special dual structure with low noise Coverage: 12m × 12m (typical value) Alarm port: normally open and normally closed alarm port, contact capacity 100mA / 30VDC

Infrared dual detector


Detection range: 8-12m Sensitivity: two level adjustable Alarm output: normally closed NC Working voltage: 9 ~ 15V DC Installation height: 2.2m ~ 3M

Water level sensor


Measuring medium: water, oil and other liquids Measurement range: 0 ~ 100m, intermediate range optional Protection grade: IP68 Load capacity: ≤ 800 Ω  Power supply range: 12 ~ 36V DC Output signal: 4 ~ 20mA / 0 ~ 5V DC