Online monitoring of wire galloping

Using imported sensors, high measurement accuracy; Use solar power supply system or coil induction to take power, easy to install and maintain; Flexible communication mode, support ZIGBEE/WIFIGSM CDMA/GPRS and 4G network; It is an industrial-grade product, using a waterproof metal shell, anti-electromagnetic interference, suitable for various harsh climate environments; the system adopts a low-power design, and adopts a dynamic power management strategy to meet power saving requirements; Equipped with complete background software. With functions such as data storage, historical data query, report, printing, graph drawing, etc., it can conduct qualitative and quantitative analysis of the wire condition; Support controlled collection mode and automatic collection mode, the sampling interval (5 minutes ~ 24 hours), alarm threshold and other parameters can be set through the background software: support the use of mobile phones for data query and alarm reception; Meet the State Grid Corporation corporate standard "General Technical Specifications for Transmission Line Condition Monitoring Devices" (Q/GDw 242-2010.

Keyword:

Power IoT sensors Smart power distribution Internet of Things Smart cable tunnel gallery Smart power generation Internet of Things Smart Internet of Things

Free consultation telephone:

Product Details

Measuring range: amplitude 0m~10m; frequency 0.1Hz-5Hz; amplitude measurement resolution: 0.1m; frequency measurement resolution: 0.1Hz;

Working environment: temperature: -40℃~~+85℃: relative humidity: ≤100%; atmospheric pressure: 550hPa~1060hPa; protection level: IP65;

Collecting unit weight: elkgi

Applicable objects: 10KV~500KV high voltage transmission lines.

Working power consumption: 5W; standby power consumption ≤0.1W;

The power supply mode of the monitoring sub-station host: solar + battery, input voltage + 12~24V; battery life: ≥3 years, continuous power supply for more than 30 days without external charging:

Acquisition unit power supply mode: large-capacity lithium battery, can work continuously for more than 3 years,

MTBF: ≥80000 hours;

Related Products

Current monitoring sensor of arrester in switchgear


Full current measurement range: 0.050 ~ 5.000mA Full current measurement error: ± (standard reading ×1%+5μA) Record the cumulative discharge times :0 ~ 99 times Power supply: DC24V Communication interface: RS-485

Ground resistance sensor


Power supply: dc6 ~ 12V Range: 0.01 Ω- two hundred Ω  Accuracy: ± 2%rdg ± 3dgt(20℃ ± 5 ℃, below 70% RH) Communication mode: RS485 Protection grade: IP54

High frequency current sensor


Sensitivity: 5pc Detection frequency band: 50KHz ~ 100MHz Signal output: RS485 Installation position: cable connector ground wire Installation mode: clamp type, clamping

Tilt sensor


Range: ± thirty °  Voltage: 9-35v Output mode: RS485 IP67 protection level

Infrared thermal imaging camera of switch cabinet


Thermal imaging resolution: 160 * 120 Visible light resolution: 200W Power supply: dc12-24 V Temperature range: - 20 ℃ ~ 150 ℃ Accuracy: ± 2 ℃ or 2% of the reading (take the maximum absolute value)

Space UHF PD sensor


Detection frequency band: 300 ~ 1500mhz Protection grade: IP65 Collect the discharge amplitude and phase The service life is more than 8 years

Micro weather sensor


Temperature: measuring range - 40 ~ 60 ℃ ° C Accuracy ± zero point one ° C; two Temperature: measurement range 0 ~ 100% RH Air pressure: measuring range: 10 ~ 1300 Wind speed measurement range: 0-75 M / S

Switch cabinet partial discharge sensor (UHF)


The system adopts UHF principle to conduct local discharge monitoring of high voltage switchgear to ensure the effective monitoring data, and increase system reliability. Ultra low power consumption and 485 bus communication mode are adopted. It is applicable to switch cabinet and ring network cabinet. Each cabinet is equipped with one set to realize the power / qualitative measurement of local discharge. It can be directly connected to the system host without the limitation of host channel.)

Switch cabinet partial discharge sensor (UHF + AE two in one)


The system adopts UHF + AE principle Ultra low power consumption and 485 bus communication mode are adopted, It is suitable for switch cabinet and ring main unit to realize the quantity / qualitative measurement of partial discharge

Intelligent air conditioning / dehumidification linkage device


AC / dc220v power supply is adopted Allowable deviation - 20% ~ + 20% Control output node capacity: AC / dc220v, ≥ 8A Support 2-4 independent node output capability

Intelligent light control unit


Output mode: switch type, realize local and remote control of lighting Wall mounted / 2U rack mounted Using brand devices to ensure reliability Size (mm): 480mm long × 85mm wide × 340mm deep

Intelligent water pump control unit


Output mode: switch type, realize the linkage control of water pump Wall mounted / 2U rack mounted, Using brand devices to ensure reliability Size (mm): 480mm long × 85mm wide × 340mm deep

Welcome your message consultation

Our staff will contact you within 24 hours (weekdays), if you need other services, please call the service hotline:0519-85851518