On-line monitoring system for ultra-high frequency partial discharge of transformer

System detection frequency band: 300MHz~1500MHz; Minimum monitorable: -75dBm discharge capacity in the laboratory, -70 dBm discharge capacity in the field; The system can measure discharge capacity, discharge phase, discharge times, and discharge pulse resolution is less than 10μs, and can provide relevant statistical parameters according to customer requirements; The system can display power frequency periodic discharge graphs, two-dimensional (Q-φ, N-φ, N-Q) and three-dimensional (N-Q-φ) discharge spectra; Provides many functions such as discharge development trend analysis, alarm setting, historical query and report printing; The system can automatically start monitoring at regular intervals to realize the automation of the entire monitoring process, and it can also start and close the monitoring system manually in real time; The system has built-in four standard discharge mode libraries, which can identify discharge types, evaluate insulation defects caused by different types of discharge trends, and give alarms for abnormal conditions; The system structure complies with the Smart Substation Guidelines Q / GDW 383-2009 "Technical Guidelines for Smart Substations", which is suitable for the intelligent transformation of substations and new intelligent substations. The data server in the system station control layer cabinet has CAC function, built-in I2 data interface and directly communicates with the current state monitoring system of power transmission and transformation equipment of various provincial companies.

Keyword:

Power IoT sensors Smart power distribution Internet of Things Smart cable tunnel gallery Smart power generation Internet of Things Smart Internet of Things

Free consultation telephone:

Product Details

System detection frequency band: 300MHz~1500MHz;

Minimum monitorable: -75dBm discharge capacity in the laboratory, -70 dBm discharge capacity in the field;

The system can measure discharge capacity, discharge phase, discharge times, and discharge pulse resolution is less than 10μs, and can provide relevant statistical parameters according to customer requirements;

The system can display power frequency periodic discharge graphs, two-dimensional (Q-φ, N-φ, N-Q) and three-dimensional (N-Q-φ) discharge spectra;

Provides many functions such as discharge development trend analysis, alarm setting, historical query and report printing;

The system can automatically start monitoring at regular intervals to realize the automation of the entire monitoring process, and it can also start and close the monitoring system manually in real time;

The system has built-in four standard discharge mode libraries, which can identify discharge types, evaluate insulation defects caused by different types of discharge trends, and give alarms for abnormal conditions;

The system structure complies with the Smart Substation Guidelines Q / GDW 383-2009 "Technical Guidelines for Smart Substations", which is suitable for the intelligent transformation of substations and new intelligent substations.

The data server in the system station control layer cabinet has CAC function, built-in I2 data interface and directly communicates with the current state monitoring system of power transmission and transformation equipment of various provincial companies.

Related Products

Maintenance-free intelligent transformer breather


The maintenance-free transformer breather is an air dehumidification and purification device used for oil-immersed transformers, instrument transformers, on-load tap changers, or other electrical equipment filled with insulating liquid. The maintenance-free transformer breather is installed at the air inlet of the instrument transformer's oil storage tank. When the transformer or instrument transformer operates, the oil volume changes due to temperature variations, causing the gas inside the oil storage tank to breathe through the desiccant. Air passes through the filter at the bottom of the desiccant and the glass jar filled with silica gel into the transformer, ensuring that the inhaled air is dry (moisture is adsorbed by the desiccant) and clean (dust and impurities are blocked by the filter), thereby maintaining the cleanliness and insulation strength of the transformer oil.

JC-OM700-EE Wireless Expansion Joint Sensor


The JC-OM700-EE wireless expansion joint sensor achieves online monitoring of expansion joint compensation by modifying the existing mechanical vernier caliper of GIS/GIL expansion joints or adding a digital expansion joint displacement sensor. The wireless expansion joint sensor uses a high-speed ARM chip as the main controller and a high-precision displacement sensor to sample and calculate the displacement data of the measured object in real time. It can upload data to the host computer via wireless LoRa and wired RS485.

Current monitoring sensor of arrester in switchgear


Full current measurement range: 0.050 ~ 5.000mA Full current measurement error: ± (standard reading ×1%+5μA) Record the cumulative discharge times :0 ~ 99 times Power supply: DC24V Communication interface: RS-485

Ground resistance sensor


Power supply: dc6 ~ 12V Range: 0.01 Ω- two hundred Ω  Accuracy: ± 2%rdg ± 3dgt(20℃ ± 5 ℃, below 70% RH) Communication mode: RS485 Protection grade: IP54

High frequency current sensor


Sensitivity: 5pc Detection frequency band: 50KHz ~ 100MHz Signal output: RS485 Installation position: cable connector ground wire Installation mode: clamp type, clamping

Tilt sensor


Range: ± thirty °  Voltage: 9-35v Output mode: RS485 IP67 protection level

Infrared thermal imaging camera of switch cabinet


Thermal imaging resolution: 160 * 120 Visible light resolution: 200W Power supply: dc12-24 V Temperature range: - 20 ℃ ~ 150 ℃ Accuracy: ± 2 ℃ or 2% of the reading (take the maximum absolute value)

Space UHF PD sensor


Detection frequency band: 300 ~ 1500mhz Protection grade: IP65 Collect the discharge amplitude and phase The service life is more than 8 years

Micro weather sensor


Temperature: measuring range - 40 ~ 60 ℃ ° C Accuracy ± zero point one ° C; two Temperature: measurement range 0 ~ 100% RH Air pressure: measuring range: 10 ~ 1300 Wind speed measurement range: 0-75 M / S

Switch cabinet partial discharge sensor (UHF)


The system adopts UHF principle to conduct local discharge monitoring of high voltage switchgear to ensure the effective monitoring data, and increase system reliability. Ultra low power consumption and 485 bus communication mode are adopted. It is applicable to switch cabinet and ring network cabinet. Each cabinet is equipped with one set to realize the power / qualitative measurement of local discharge. It can be directly connected to the system host without the limitation of host channel.)

Switch cabinet partial discharge sensor (UHF + AE two in one)


The system adopts UHF + AE principle Ultra low power consumption and 485 bus communication mode are adopted, It is suitable for switch cabinet and ring main unit to realize the quantity / qualitative measurement of partial discharge

Intelligent air conditioning / dehumidification linkage device


AC / dc220v power supply is adopted Allowable deviation - 20% ~ + 20% Control output node capacity: AC / dc220v, ≥ 8A Support 2-4 independent node output capability

Welcome your message consultation