Products

Products

Product System

Wireless switch cabinet partial discharge sensor (TEV + AE two in one)


The principle of transient geoelectric wave TEV + ultrasonic AE detection is adopted Detection range: 0 ~ 60dB, resolution ± 1dB Frequency range of transient earth wave (TEV): 3mhz-100mhz Ultrasonic (AE) detection frequency range: 40KHz ± 0.5KHZ

Wireless switch cabinet partial discharge sensor (AE)


The principle of ultrasonic AE detection was adopted, Ultrasonic (AE) detection frequency range: 40KHz ± 0.5KHZ; The sensor adopts ultra-low power consumption and wireless communication mode

Wireless switch cabinet partial discharge sensor (TEV)


The principle of transient geoelectric wave TEV detection is adopted, Transient earth wave (TEV) detection frequency range: 3mhz-100mhz; The sensor adopts ultra-low power consumption and wireless communication mode

Wireless temperature sensor


Temperature measurement range: - 25 ~ + 200 ℃ Starting current: > 3a, wireless passive, CT induction power Wireless transmission, band adaptation Transmission distance up to 200 meters, maintenance free

Wireless UHF spatial amplifier sensor


Detection frequency band: 300-1500mhz Monitoring range: space partial discharge within 20 meters Protection grade: IP65 AC220V active power supply is adopted for power supply Communication mode: wireless transmission of Lora

Wireless battery monitoring device


Overall voltage monitoring range: dc0v ~ 220V Current monitoring range: 0 ~ 1000A Environmental temperature monitoring: 0 ~ 100 ℃ Measurement range of internal resistance: 0.1M Ω~ 100m Ω  Wireless communication based on Lora

Wireless intelligent door lock


The input format of the reader is Wiegand 26 / 34 (compatible with hid, EM, Mifare1 and mobile card readers under the protocol), Power supply voltage: DC12V Communication mode: Lora wireless transmission

Wireless transformer noise sensor


The power supply adopts DC12V active power supply Measurement frequency range: 20Hz ~ 12.5khz Noise measurement range: 30dB ~ 120dB Communication mode: wireless transmission of Lora

Wireless ozone sensor


Battery / active power supply is adopted for power supply O3 measurement range: 0-20ppm O3 precision:< ± 0.1ppm(25℃) Communication mode: wireless transmission of Lora

Intelligent air conditioning / dehumidification linkage device


AC / dc220v power supply is adopted Allowable deviation - 20% ~ + 20% Control output node capacity: AC / dc220v, ≥ 8A Support 4-8 independent node output capability Communication mode: 470MHz wireless communication based on Lora

Intelligent lighting linkage device


AC / dc220v power supply is adopted Allowable deviation - 20% ~ + 20% Control output node capacity: AC / dc220v, ≥ 8A Support 4-8 independent node output capability Communication mode: 470MHz wireless communication based on Lora

Intelligent fan linkage device


AC / dc220v power supply is adopted, The allowable deviation is - 20% ~ + 20%; Input voltage: DC12V / DC24V; Control output node capacity: AC / dc220v, ≥ 8a, support 4-8 independent node output capacity; Communication mode: 470MHz wireless communication based on Lora

Wireless water level sensor


Power supply voltage: lithium sub battery dc3.6v Output interface: wireless Lora Cable length: 1.6 ± 0.1 m  Insulation resistance: > 500 Measurement range: 0-5m (measurement range can be customized)

Wireless SF6 gas detector


The detector has SF6 gas concentration For SF6 detection, ultrasonic principle is adopted SF6 gas concentration measurement range: 0-3000ppm SF6 concentration overrun alarm point: 1000ppm (national standard value) Accuracy < 5% FS

Wireless smoke sensor


Wireless smoke sensor
< 12 >