SF6 gas concentration online monitoring and alarm system

J CD L/1 SF 6 gas concentration online monitoring and alarm system (hereinafter referred to as this system) is a high-tech new high-tech developed by our company for the personal protection needs of indoor staff in SF 6 switch room, combined electrical appliance (GIS) room, etc. product. This system adopts original imported sensors, combined with the powerful control capability of C P U, can monitor the concentration of SF 6 gas, oxygen content and ambient temperature and humidity online in real time, and use the bus for digital transmission of the measurement results. It can accurately and timely grasp the status of the operating equipment, and also control the exhaust air of the fan.

Keyword:

Power IoT sensors Smart power distribution Internet of Things Smart cable tunnel gallery Smart power generation Internet of Things Smart Internet of Things

Free consultation telephone:

Product Details

J CD L/1 SF 6 gas concentration online monitoring and alarm system (hereinafter referred to as this system) is a high-tech new high-tech developed by our company for the personal protection needs of indoor staff in SF 6 switch room, combined electrical appliance (GIS) room, etc. product. This system adopts original imported sensors, combined with the powerful control capability of C P U, can monitor the concentration of SF 6 gas, oxygen content and ambient temperature and humidity online in real time, and use the bus for digital transmission of the measurement results. It can accurately and timely grasp the status of the operating equipment, and also control the exhaust air of the fan.

Working voltage: AC/DC 220V±10%, 50Hz

Power consumption: <10W under rated voltage

Accuracy level: 2.5 level

SF6 gas concentration measurement range: 0-3000ppm

SF6 concentration exceeding limit alarm point: 1000ppm (national standard value), accuracy <5%FS

Oxygen content detection range: 0-25%

Hypoxia alarm point: 18% (national standard value), accuracy <1%FS

Temperature detection range: -30—+99°C (accuracy ±0.5°C)

Humidity detection range: 10-99%RH: accuracy ±0.5%RH

Fan output power contact: 6A;

Remote communication mode: 485/Ethernet

On-site host appearance size (mm): L330×W250×H65

SF6 and oxygen detection unit size (mm): L162×W150×H38

Temperature and humidity detection unit size (mm): L162×W150×H38

Monitoring historical data storage capacity: 5 million items;

Touch screen size: 7 inches

Host and detection unit installation method: wall-mounted

Working environment temperature: -25℃~70℃

Working environment humidity: ≤95%

Related Products

Current monitoring sensor of arrester in switchgear


Full current measurement range: 0.050 ~ 5.000mA Full current measurement error: ± (standard reading ×1%+5μA) Record the cumulative discharge times :0 ~ 99 times Power supply: DC24V Communication interface: RS-485

Ground resistance sensor


Power supply: dc6 ~ 12V Range: 0.01 Ω- two hundred Ω  Accuracy: ± 2%rdg ± 3dgt(20℃ ± 5 ℃, below 70% RH) Communication mode: RS485 Protection grade: IP54

High frequency current sensor


Sensitivity: 5pc Detection frequency band: 50KHz ~ 100MHz Signal output: RS485 Installation position: cable connector ground wire Installation mode: clamp type, clamping

Tilt sensor


Range: ± thirty °  Voltage: 9-35v Output mode: RS485 IP67 protection level

Infrared thermal imaging camera of switch cabinet


Thermal imaging resolution: 160 * 120 Visible light resolution: 200W Power supply: dc12-24 V Temperature range: - 20 ℃ ~ 150 ℃ Accuracy: ± 2 ℃ or 2% of the reading (take the maximum absolute value)

Space UHF PD sensor


Detection frequency band: 300 ~ 1500mhz Protection grade: IP65 Collect the discharge amplitude and phase The service life is more than 8 years

Micro weather sensor


Temperature: measuring range - 40 ~ 60 ℃ ° C Accuracy ± zero point one ° C; two Temperature: measurement range 0 ~ 100% RH Air pressure: measuring range: 10 ~ 1300 Wind speed measurement range: 0-75 M / S

Switch cabinet partial discharge sensor (UHF)


The system adopts UHF principle to conduct local discharge monitoring of high voltage switchgear to ensure the effective monitoring data, and increase system reliability. Ultra low power consumption and 485 bus communication mode are adopted. It is applicable to switch cabinet and ring network cabinet. Each cabinet is equipped with one set to realize the power / qualitative measurement of local discharge. It can be directly connected to the system host without the limitation of host channel.)

Switch cabinet partial discharge sensor (UHF + AE two in one)


The system adopts UHF + AE principle Ultra low power consumption and 485 bus communication mode are adopted, It is suitable for switch cabinet and ring main unit to realize the quantity / qualitative measurement of partial discharge

Intelligent air conditioning / dehumidification linkage device


AC / dc220v power supply is adopted Allowable deviation - 20% ~ + 20% Control output node capacity: AC / dc220v, ≥ 8A Support 2-4 independent node output capability

Intelligent light control unit


Output mode: switch type, realize local and remote control of lighting Wall mounted / 2U rack mounted Using brand devices to ensure reliability Size (mm): 480mm long × 85mm wide × 340mm deep

Intelligent water pump control unit


Output mode: switch type, realize the linkage control of water pump Wall mounted / 2U rack mounted, Using brand devices to ensure reliability Size (mm): 480mm long × 85mm wide × 340mm deep

Welcome your message consultation

Our staff will contact you within 24 hours (weekdays), if you need other services, please call the service hotline:0519-85851518