Tunnel electronic manhole cover monitoring system

The intelligent manhole cover monitoring system uses the current advanced wireless communication technology, power supply technology, and sensor technology to incorporate the state of the manhole cover, the state of the underground environment, the opening of the manhole cover, and the inspection of the manhole cover into the unified maintenance management system, and establish the corresponding alarm processing Mechanism, the status of the manhole cover and the alarm content are displayed through the electronic map. If the manhole cover is stolen or damaged, the monitoring personnel can go to the scene to deal with it in time and quickly Resolve safety hazards. The system can realize the data collection, real-time display, diagnostic analysis, fault alarm of various security signals of the manhole cover, so that the dispatch center, operation and maintenance station, and management departments can intuitively understand and master the operation of the underground pipeline network

Keyword:

Power IoT sensors Smart power distribution Internet of Things Smart cable tunnel gallery Smart power generation Internet of Things Smart Internet of Things

Free consultation telephone:

Product Details

Technical characteristics

1. Modular design is adopted on the host hardware, and the whole machine has no rotating equipment

2. The host hardware supports hot-swappable expansion technology to achieve system load balancing and capacity expansion

3. The communication supports IEC 60870—5—103 and DL-T860 communication protocol

4. Realization of environmental data collection and abnormal alarm linkage technology

5. The system applies soft bus technology to ensure seamless switching between main and standby equipment

6. Use electronic maps for equipment management and status display

7. It adopts wired and wireless GPRS/SMS to realize communication with field equipment

8. Use SMS/3G/4G to realize real-time alarm/notification with maintenance personnel

Related Products

Current monitoring sensor of arrester in switchgear


Full current measurement range: 0.050 ~ 5.000mA Full current measurement error: ± (standard reading ×1%+5μA) Record the cumulative discharge times :0 ~ 99 times Power supply: DC24V Communication interface: RS-485

Ground resistance sensor


Power supply: dc6 ~ 12V Range: 0.01 Ω- two hundred Ω  Accuracy: ± 2%rdg ± 3dgt(20℃ ± 5 ℃, below 70% RH) Communication mode: RS485 Protection grade: IP54

High frequency current sensor


Sensitivity: 5pc Detection frequency band: 50KHz ~ 100MHz Signal output: RS485 Installation position: cable connector ground wire Installation mode: clamp type, clamping

Tilt sensor


Range: ± thirty °  Voltage: 9-35v Output mode: RS485 IP67 protection level

Infrared thermal imaging camera of switch cabinet


Thermal imaging resolution: 160 * 120 Visible light resolution: 200W Power supply: dc12-24 V Temperature range: - 20 ℃ ~ 150 ℃ Accuracy: ± 2 ℃ or 2% of the reading (take the maximum absolute value)

Space UHF PD sensor


Detection frequency band: 300 ~ 1500mhz Protection grade: IP65 Collect the discharge amplitude and phase The service life is more than 8 years

Micro weather sensor


Temperature: measuring range - 40 ~ 60 ℃ ° C Accuracy ± zero point one ° C; two Temperature: measurement range 0 ~ 100% RH Air pressure: measuring range: 10 ~ 1300 Wind speed measurement range: 0-75 M / S

Switch cabinet partial discharge sensor (UHF)


The system adopts UHF principle to conduct local discharge monitoring of high voltage switchgear to ensure the effective monitoring data, and increase system reliability. Ultra low power consumption and 485 bus communication mode are adopted. It is applicable to switch cabinet and ring network cabinet. Each cabinet is equipped with one set to realize the power / qualitative measurement of local discharge. It can be directly connected to the system host without the limitation of host channel.)

Switch cabinet partial discharge sensor (UHF + AE two in one)


The system adopts UHF + AE principle Ultra low power consumption and 485 bus communication mode are adopted, It is suitable for switch cabinet and ring main unit to realize the quantity / qualitative measurement of partial discharge

Intelligent air conditioning / dehumidification linkage device


AC / dc220v power supply is adopted Allowable deviation - 20% ~ + 20% Control output node capacity: AC / dc220v, ≥ 8A Support 2-4 independent node output capability

Intelligent light control unit


Output mode: switch type, realize local and remote control of lighting Wall mounted / 2U rack mounted Using brand devices to ensure reliability Size (mm): 480mm long × 85mm wide × 340mm deep

Intelligent water pump control unit


Output mode: switch type, realize the linkage control of water pump Wall mounted / 2U rack mounted, Using brand devices to ensure reliability Size (mm): 480mm long × 85mm wide × 340mm deep

Welcome your message consultation