Multifunctional partial discharge detection analyzer

The partial discharge detection analyzer (BYPDM) is a multi-functional, multi-purpose portable device, suitable for partial discharge (Partial Discharge, PD) live detection of transformers, GIS, cables, switch cabinets and other equipment. The partial discharge detector also comes with partial discharge acquisition and analysis software, with a flexible user interface, which is convenient for you to accurately judge the characteristics of partial discharge.

Keyword:

Power IoT sensors Smart power distribution Internet of Things Smart cable tunnel gallery Smart power generation Internet of Things Smart Internet of Things

Free consultation telephone:

Product Details

Professional partial discharge analysis software

For partial discharge signal characteristics, pulse sequence analysis (PSA), frequency domain spectrum analysis (Frequency Domain Spectral, FDS), wavelet analysis (Wavelet Analysis, WA), and Time-Frequency map (TF map) can be used. ) And other different digital signal processing technologies to help you obtain true and effective partial discharge information. In addition, the partial discharge pattern recognition algorithm is based on the partial discharge phase spectrum (Phase Resolved Partial Discharge, PRPD) for multivariate statistical distribution (Multivariate Statistical Distribution, MSD), which can be more typical for internal discharge, corona discharge, floating potential discharge, etc. The type of discharge is classified and identified.

l Localization function of partial discharge defects

The location of cavity structures such as transformers and GIS are realized by using the spatial location algorithm (Location of Conic Axis, LOCA) of plane intersection as the mathematical model, and the cable fault location is realized by Time Domain Reflector (TDR) technology.

3. Technical indicators

l Signal input channel performance: four high-speed input channels (analog bandwidth 170kHz~1.5GHz, digital sampling rate 5GS/s.), and eight low-speed input channels (analog bandwidth DC~1.3MHz, digital sampling rate 3MS/s.) .

l Ultra-wide frequency band: Pulse current PD signal 100kHz~50MHz, UHF PD signal 300MHz~1.5GHz, Ultrasonic PD signal 20kHz~400kHz.

l Resolution of partial discharge pulse: double pulse resolution <1µs, pulse repetition frequency 1MHz.

l Partial amplifier signal conditioning parameters: the gain is adjustable in the range of -6dB to +54dB, with a step of 6dB; there are seven options for UHF broadband limitation: 20MHz, 100MHz, 200MHz, 350MHz, 650MHz, 750MHz and full passband. Both pulse current and ultrasonic PD signal have programmable filter design.

l Power supply: AC power supply voltage 200V~240V (47~63Hz) wide voltage range.

l Control mode: local, remote network (LAN, WIFI, optical fiber).

Related Products

Current monitoring sensor of arrester in switchgear


Full current measurement range: 0.050 ~ 5.000mA Full current measurement error: ± (standard reading ×1%+5μA) Record the cumulative discharge times :0 ~ 99 times Power supply: DC24V Communication interface: RS-485

Ground resistance sensor


Power supply: dc6 ~ 12V Range: 0.01 Ω- two hundred Ω  Accuracy: ± 2%rdg ± 3dgt(20℃ ± 5 ℃, below 70% RH) Communication mode: RS485 Protection grade: IP54

High frequency current sensor


Sensitivity: 5pc Detection frequency band: 50KHz ~ 100MHz Signal output: RS485 Installation position: cable connector ground wire Installation mode: clamp type, clamping

Tilt sensor


Range: ± thirty °  Voltage: 9-35v Output mode: RS485 IP67 protection level

Infrared thermal imaging camera of switch cabinet


Thermal imaging resolution: 160 * 120 Visible light resolution: 200W Power supply: dc12-24 V Temperature range: - 20 ℃ ~ 150 ℃ Accuracy: ± 2 ℃ or 2% of the reading (take the maximum absolute value)

Space UHF PD sensor


Detection frequency band: 300 ~ 1500mhz Protection grade: IP65 Collect the discharge amplitude and phase The service life is more than 8 years

Micro weather sensor


Temperature: measuring range - 40 ~ 60 ℃ ° C Accuracy ± zero point one ° C; two Temperature: measurement range 0 ~ 100% RH Air pressure: measuring range: 10 ~ 1300 Wind speed measurement range: 0-75 M / S

Switch cabinet partial discharge sensor (UHF)


The system adopts UHF principle to conduct local discharge monitoring of high voltage switchgear to ensure the effective monitoring data, and increase system reliability. Ultra low power consumption and 485 bus communication mode are adopted. It is applicable to switch cabinet and ring network cabinet. Each cabinet is equipped with one set to realize the power / qualitative measurement of local discharge. It can be directly connected to the system host without the limitation of host channel.)

Switch cabinet partial discharge sensor (UHF + AE two in one)


The system adopts UHF + AE principle Ultra low power consumption and 485 bus communication mode are adopted, It is suitable for switch cabinet and ring main unit to realize the quantity / qualitative measurement of partial discharge

Intelligent air conditioning / dehumidification linkage device


AC / dc220v power supply is adopted Allowable deviation - 20% ~ + 20% Control output node capacity: AC / dc220v, ≥ 8A Support 2-4 independent node output capability

Intelligent light control unit


Output mode: switch type, realize local and remote control of lighting Wall mounted / 2U rack mounted Using brand devices to ensure reliability Size (mm): 480mm long × 85mm wide × 340mm deep

Intelligent water pump control unit


Output mode: switch type, realize the linkage control of water pump Wall mounted / 2U rack mounted, Using brand devices to ensure reliability Size (mm): 480mm long × 85mm wide × 340mm deep